Technical Bulletin

To:  DW® Customers

Date:  May 9, 2023

Re:  Arecont AV20576DN Compatibility Issue Fix

 

Arecont AV20576DN and DW Spectrum Compatibility Fix

-----------------------------------

Relevant DW Product:  DW Spectrum Server Software

Relevant Version:  v5.0.0.36183

Last Edit: May 9, 2023

-----------------------------------

 

Compatibility Issue

As of May 2023, the Arecont AV20576DN camera model was found to have compatibility issues when interfacing with the DW Spectrum Server software application. This compatibility issue can be characterized by:

  1. DW Spectrum Server does not discover the AV20576DN camer
  2. Signal/stream fails when trying to connect with the AV20576DN camera.

To resolve this issue until an official software update can be released for DW Spectrum IPVMS, our developers have provided a JSON resource that can be implemented to the DW Spectrum Server.

This article will outline where to copy the JSON file in the DW Spectrum Server folder to implement this fix.

 

**NOTE:  Making changes to the core files and configurations of the DW Spectrum Server files is not recommended unless necessary to resolve a specific issue. Please consult with your Digital Watchdog service representative or with DW Support for clarification if you are unsure if this fix applies to your needs or to an ongoing issue.

 

Downloading the File

Use the link below to obtain the JSON file. This file will be compressed into a folder upon download and compression software (Winzip, Winrar, etc.) is needed to unzip the folder.

  • JSON file:

https://digital-watchdog.com/admin/assets/_downloads/resource_data.zip

 

Applying the JSON File to DW Spectrum Server

After downloading the JSON file from the link above follow the instructions below to implement this fix.

  1. If the AV20576DN camera is already added to the DW Spectrum Server and appears within its Resource Tree (left-panel of the client), remove the camera from the DW Spectrum Server.
    1. Right-click on the camera in the Resource Tree and select “Delete” to remove the camera.
    2. If the camera is automatically re-discovered, you can disable the autodiscovery feature in the “System Administration > General > System Settings” menu. Be sure to reactivate this setting upon completing this guide as needed.
  2. Stop the mediaserver application.
    1. For Windows – Right-click on the ‘DW’ icon that appears in the Windows system try and select “Stop Server (started)”.

 

    1. For Ubuntu Linux – Open the Terminal application and use the following commands.
      1. To gain root administrator rights, use the command:

sudo su

      1. The system will request the administrator password. The text characters will be hidden and not display as you type. For DW Blackjack units, the default password is:
        • DW Blackjack units sold with Ubuntu 16.04 – admin
        • DW Blackjack units sold with Ubuntu 18.04 – Dw5pectrum
      2. Once root administrator rights have been gained, use the command:

service digitalwatchdog-mediaserver stop

 

  1. Copy and paste the downloaded files into the following folder locations.
    1. resource_data.jsonfile location:
      • For Windows – C:\Program Files\Digital Watchdog\DW Spectrum\MediaServer
      • For Ubuntu Linux – /opt/digitalwatchdog/mediaserver/bin/

 

  1. Start the mediaserver application again.
    1. For Windows – Right-click on the media server icon that appears in the Windows system tray and select “Start Server (stopped)”.
    2. For Ubuntu Linux – In the Terminal application and as the root administrator, use the command:

service digitalwatchdog-mediaserver start

 

  1. Once the DW Spectrum Server application has finished restarting, you may add the AV20576DN camera to the system and test to confirm that the streaming issue has been resolved.

 

This completes the compatibility issue resolution for the Arecont AV20576DN compatibility issue with DW Spectrum.

 

 

 

For More Information or Technical Support

DW Technical Support:

Toll-free:  866.446.3595

https://www.digital-watchdog.com/contact-tech-support/

__________________________________________________________________________________

866.446.3595              [email protected]        www.digital-watchdog.com

Rev: 05/23                              Copyright © DW. All rights reserved. Specifications and pricing subject to change without notice.                            

scroll to top icon